24 visiting now: 12 France France flag 6 USA USA flag 2 China China flag 1 Vietnam Vietnam flag 1 Ghana Ghana flag 1 Ireland Ireland flag 1 Netherlands Netherlands flag

Hyva 405 Ct Pt Analyzer Current Transformer Potential - China

price: contact company for price

Introduction

Tests for Current Transformer:

1 Excitation curve and parameters test

2 Turns ratio test

3 Ratio and phase error test

4 Polarity mark check

5 Winding resistance measurement

6 Secondary loop burden measurement

7 Error line curve test for protection CT

8 Transient CT parameters test

9 CT nameplate guess

10 Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

1 Turns ratio test

2 Ratio error and phase angle error test

3 Polarity test

4 Secondary burden test

5 Winding resistance test

Application

CT PT Tester application

1 CT nameplate check

2 CT parameters check in work burden

3 CT transient parameters analysis

4 CT ratio and phase error calibration

5 PT routine test

Technical index

1 Test standards: IEC60044- 1, IEC60044- 6, IEC60044- 2, IEC60044- 5, C57.13

2 Power supply: AC220V±10% , 50/ 60Hz±10%

3 Voltage output: 0.1~180V ( AC)

4 Current output: 0.001~5A( RMS)

5 Power output: 500VA

6 Maximum knee voltage measurement: 45KV

7 Current measurement:

Range: 0~10A ( automatically change range in 0.1/ 0.4/ 2/ 10A)

Error: <±0.1% +0.01% FS

8 Voltage measurement:

Range: 0~200V ( automatically change range in 1V/ 10V/ 70V/ 200V)

Error: < ±0.1% +0.01% FS

9 Turns ratio measurement:

Range: 1~35000

1~2000 error<0.05%

2000~5000 error<0.1%

5000~35000 error<0.2%

10 Phase measurement: error: ±2min; resolution: 0.01min

11 Winding resistance measurement:

Range: 0~8kΩ ( automatically change range in 2ohm/ 20ohm/ 80ohm/ 800ohm/ 8kohm)

Error: < 0.2% RDG+0.02% FS

Maximum resolution: 0.1mΩ

12 Temperature measurement: - 50~100 Celsius degree; error<3 Celsius degree

13 CT Secondary burden:

Range: 0~ 160ohm ( automatically change range in 2ohm/ 20ohm/ 80ohm/ 160ohm)

Error: <0.2% RDG+0.02% FS

Maximum resolution: 0.001ohm

14 PT Secondary burden:

Range: 0~ 80kohm ( automatically change range in 800ohm/ 8kohm/ 80kohm)

Error : <0.2% RDG+0.02% FS

Maximum resolution: 0.1ohm

15 PT ratio measurement:

Range: 1~35000

1~10000 error<0.1%

10000~35000 error<0.2%

16 PT ratio error measurement: Typical error <0.05% , Maximum Error<0.1%

17 PT phase angle measurement: maximum error < 3min

18 Make evaluation for test results according to selected standards

19 Make word report for test result

20 Make word reports one time for multi- group test records on the PC

21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test

22 Compare excitation curves with saved excitation curves in the same window

23 Memory capacity: >1000 groups test results

24 Working condition: temperature: - 10℃ ~ 50℃ ; moist: ≤ 90%

25 Size: 485mm×356mm×183mm

26 Weight: <15kg

Tags:

ct analyzer, ct pt analyzer, current transformer analyzer, potential transformer analyzer, testing equipment, lab test equipment, made in china, alibaba gold supplier, measuring and testing equipment.


Company Contact:


  • Phone: 008615827280740

  • Address: 4F,Building 7,Optical Valley International Headqua, Wuhan, China

  • Email: Email


Published date: March 4, 2015 -

  • Business Description: Wuhan huaying electric power tech & science co.,ltd,main products

    include ct pt analyzer,insulating oil tester, circuit breaker analyzer,

    ttr tester, winding resistance tester, tangent delta tester, relay

    tester,primary current injection tester,frequency response

    analyzer,hipot tester, and other hv test equipment.Founded in 1997,

    engaged in designing, manufacturing and exporting of electrical test

    equipment.

Related listings



  • Ct Pt Test Set Current Transformer Analyzer Potential
    Ct Pt Test Set Current Transformer Analyzer Potential
    Electronics Testing - Wuhan Huaying Electric Power Tech & Science Co.,lt - China - March 4, 2015 - contact company for price

    Introduction Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for ...

  • Ph061 Pen Type Ph Meter
    Ph061 Pen Type Ph Meter
    Electronics Testing - Kelilong Electron Co.,Ltd - China - March 1, 2015 - contact company for price

    Description: KL- 061 ph meter is a great hand held pH meter with a large easy to read display, simple operation and easy features. Suitable for many different applications. it makes testing pH easy. The meter is light weight and will fit in your pock...

  • Ph 0101 Folding Three In One Tester
    Ph 0101 Folding Three In One Tester
    Electronics Testing - Kelilong Electron Co.,Ltd - China - March 1, 2015 - contact company for price

    Descriptions: Folding design feature to use expediently Replaceable pH electrode Clear LCD display featuring both pH, temperature and humidity The KL- 0101 offers increased accuracy when measuring solutions at different temperatures as it automatical...



Safe Trade Tips

  • Ask for business references and check them
  • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
  • Verify their business via their local Chamber of Commerce
  • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
  • Get to know more about scams to avoid: Internet Crime Complaint Center - International Financial Scams
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"