60 visiting now: 41 USA USA flag 10 Singapore Singapore flag 9 Canada Canada flag 3 UK UK flag 1 Australia Australia flag 1 Germany Germany flag

Highlighted Companies

  • Eagle Eyes China Inspection Company (China): Eagle Eyes (CHINA) Quality Inspection Co.,Ltd. is a professional Third... https://www.china-qualityinspection.com
  • Verify China Company Service (China): Verify China Company is founded by a group of people who work years in international trade... https://verifychinacompany.com/
  • Ydq 2 Rain Proof Electroscope - China

    price: contact company for price

    First, the overview: The electroscope is the power system and industrial and mining enterprises operating electricity necessary security tools, it is used to detect 0.1kV-500kV lines or equipment is running with the power frequency voltage to ensure that the staff in the maintenance of power outage Personal safety.

    The production of GDY-II-type sound and light electroscope, is divided into 0.1kV to 500kV seven voltage level products for the user to choose the order according to the actual operating voltage level.

    When it is audible, it sends out sound and light double alarm signal to prompt the staff to be seized line or equipment charged.

    The electroscope in the electric power industry electrical safety equipment testing center through the type test, the main technical indicators in line with DL740-2000 power industry standards and international IEC technical standards.

    Products through the provincial-level appraisal and review by the power industry.

    Second, the use and precautions:

    (A), before use, according to the rated voltage of electrical equipment to choose the appropriate voltage level qualified electroscope.

    (B), electroscope must be self-test before use: the method is to press the self-test button with your finger, the indicator light intermittent flash, and issued an intermittent alarm sound, indicating the instrument is normal.

    (C), for more than 10kV inspection work, must be "electrical safety work order" implementation, the staff wearing insulated gloves, wear insulated boots, and to ensure safe distance of live equipment.

    (D), inspection, the staff holding the grip below the electrical part of the ring, and in accordance with the "Electrical Safety Working Rules" requirement, the first electrical facilities on the test, verify the electroscope does the performance intact, Can be used, the rainy day fog days shall not use the instrument.

    3, regular experiments: In order to protect the safety of people and equipment, according to "electrical safety work order" provides that the electroscope should be insulation for regular pressure experiments, start the experiment, wet place for three months, dry place six months, Direct, should stop using.

    Fourth, carry and keep:

    1) Avoid dropping, squeezing, strong shock, vibration, do not use corrosive chemical solvents and cleaning solution scrub.

    2) Do not exposure to open sun exposure, often kept clean, dry place.

    3) The electroscope (indicator) uses the SR44 button and battery (1.5 volts) 4, when the self-test switch (such as the indicator is weak) (including abnormal) should be replaced


    Company Contact:


    • Phone: 0086 317 5080000

    • Address: Appliance Electrical Materials Industrial Park,Suning, CangZhou , Hebei , China

    • Email: Email

    Published date: March 9, 2017

    • Business Description: Manufacture and sale : high and low voltage electrical appliances, switches and complete sets of equipment, lightning arrester, line fittings, Safety tools, Installation and maintenance of copper wire electromagnetic insulator, new energy operation and development, operational management.

      Our Products:

      - power transformer s13 m oil type transformers

      - transformers

      - 10kv switchyard

      - box type sub section posts

      - box type substation 10kv

    Related listings



    • Sub Section Of The Stick
      Sub Section Of The Stick
      Electrical Engineering - 7.Hebei Box-type Transformer Co., Ltd. - China - March 9, 2017 - contact company for price

      Pull brake rod, also known as insulated operating rod, insulated operating rod, insulated rod, high pressure operating rod, Main use: for high and low voltage switch, pull the gate and for live line clamp. Pull brake lever (also known as grams of rod...

    • Flat Screw Rods
      Flat Screw Rods
      Electrical Engineering - 7.Hebei Box-type Transformer Co., Ltd. - China - March 9, 2017 - contact company for price

      The main components of the product by the wire hook line, or the mother row flat line clip, jumper short ground grounding line, wiring nose, manifold, grounding clip or five anti-lock chuck, ground steel and grounding operation bar composition. Clamp...

    • Hand Grip Rods
      Hand Grip Rods
      Electrical Engineering - 7.Hebei Box-type Transformer Co., Ltd. - China - March 9, 2017 - contact company for price

      The main components of the product by the wire hook line, or the mother row flat line clip, jumper short ground grounding line, wiring nose, manifold, grounding clip or five anti-lock chuck, ground steel and grounding operation bar composition. Clamp...



    Safe Trade Tips

    • Ask for business references and check them
    • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
    • Verify their business via their local Chamber of Commerce
    • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
    • Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
    • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"