Primary Current Injection Tester - China

price: contact company for price


HYPCIT series primary current injection tester is applied in power system for circuit breaker test, protection system test and current transformer test. The current injection tester generates a high current from power supply to simulate the rated current or fault current in the primary circuit of power equipment.


1) High current output injected to the main circuit of power line to simulate the fault current. And then check whether the protection system will be operated according to the design

2) High current output injected to the primary of current transformer and then measure the inducted current from secondary by error measurement instrument to check the ratio error and phase displacement of CT

3) High current output injected to the main circuit of circuit breaker to simulate the rated current in primary. And then check the stability of circuit breaker according to the temperature rise procedure.

4) Considered as a AC high current source in power equipment or cable test.

Primary current injection tester technical index:

1 Power supply: AC220V or AC 400V, 45Hz~65Hz. The power supply voltage is depends on the power output capacity. Detail information is as table 1.

2 Typical output current: 500A or 1000A or 2000A

Typical output capacity 3KVA or 5KVA or10KVA or15KVA

It can be customized according to your requirements from above specs

3 Impendence voltage: 8%

4 Idle current: 6%

5 Current distortion <5%

6 Current is measured from the secondary of current transformer which is installed in the internal of the current booster. The display unit is 4 and 1/ 2 digitals current meter. Maximum measurement error 0.5% RDG+5D.

7 Timer indication of test running is an optional configuration. The timer could be customized according to the requirement of customer from the follow list:

1) 4 digital timer from 0~9999s / 0~999.9s / 0~99.99s, accuracy 0.5% RDG+5D

2) 5 digital timer from 0~99999s / 0~9999.9s / 0~999.99s, accuracy 0.2% RDG+2D

3) 6 digital timer from 0~999999s / 0~99999.9s / 0~9999.99s, accuracy 0.1% RDG+1D

8 work temperature: 0~40 C, Humidity <90%

Company Contact:

  • Phone: 008615827280740

  • Address: 4F,Building 7,Optical Valley International Headqua, Wuhan, China

  • Email: Email

Published date: March 13, 2015 -

  • Business Description: Wuhan huaying electric power tech & science co.,ltd,main products

    include ct pt analyzer,insulating oil tester, circuit breaker analyzer,

    ttr tester, winding resistance tester, tangent delta tester, relay

    tester,primary current injection tester,frequency response

    analyzer,hipot tester, and other hv test equipment.Founded in 1997,

    engaged in designing, manufacturing and exporting of electrical test


Related listings

  • Outdoor High Voltage Vacuum Circuit Breaker
    Outdoor High Voltage Vacuum Circuit Breaker
    Equipment - Electrical - DNK (Xiamen) Electrical Co.,Ltd. - China - March 11, 2015 - contact company for price

    Description & Application The rated voltage of VSB1 AC outdoor high voltage vacuum circuit breaker include two classes of 12kV & 24kV. Both of them belong to 50Hz three- phase distribution equipment. It adopts vacuum arc extinction and SF6 gas as ins...

  • Single Phase 60hz To 50hz Frequency Converter
    Single Phase 60hz To 50hz Frequency Converter
    Equipment - Electrical - Frequency Converter 60Hz 50Hz - USA - January 17, 2015 - contact company for price

    The simplest method of creating a good 3 phase AC power source from a single phase 50Hz/ 60Hz source is to mechanically drive a 3 phase motor from a single phase 60Hz to 50Hz frequency converter. Other methods of accomplishing this electrically are r...

  • Frequency Converter 60hz 50hz 400hz
    Frequency Converter 60hz 50hz 400hz
    Equipment - Electrical - Frequency Converter 60Hz 50Hz - USA - January 17, 2015 - contact company for price

    If its an AC frequency converter whose nameplate indicates three phase 50Hz/ 60Hz or 400Hz. Then its possible to change from parallel star to series star or vice versa ( RESTRAPPING) . But if the plate indicates single phase 60Hz to 50Hz frequency co...

Safe Trade Tips

  • Ask for business references and check them
  • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
  • Verify their business via their local Chamber of Commerce
  • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
  • Get to know more about scams to avoid: Internet Crime Complaint Center - International Financial Scams
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"