43 visiting now: 29 USA USA flag 4 UK UK flag 3 Australia Australia flag 3 Canada Canada flag 1 India India flag 1 Indonesia Indonesia flag 1 Ireland Ireland flag 1 Russia Russia flag 1 Singapore Singapore flag 1 Finland Finland flag

Highlighted Companies

E6000 Handheld Power Quality Analyzer - China

price: contact company for price

Features

Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues.

Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV

Measure all three phases and neutral: With included four current probes

System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard

View graphs and generate reports: With included analysis software

Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals.

Mains signaling: Measure interference from ripple control signals at specific frequencies

Inrush mode: For troubleshooting nuisance circuit breaker tripping.

AutoTrend: Every measurement you see is always automatically recorded, without any setup.

Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.

Battery Life: Seven hours operating time per charge on NiMH battery pack

High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance

• Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever.

• Easy to wiring

• It can operate directly to the line under test under the circumstances that the Power Grid without interrupt.

• Multi-range current switching

• based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy.

Applications

Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online

Predictive maintenance - detect and prevent power quality issues before they cause downtime

Quality of service compliance - validate incoming power quality at the service entrance

Long-term analysis - uncover hard-to-find or intermittent issues

Load studies - verify electrical system capacity before adding loads

Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices.

Specifications

Measurement Items

Be measured Type of measurement

RMS Voltage Voltage

RMS Current Current

Frequency Deviation Frequency

Three-phase Unblanced Voltage, Current

Voltage fluctuations Voltage

Flicker Voltage

Harmonics and inter-harmonics, higher harmonic Voltage, current

Power Active, reactive, apparent power factor

Event log Transient pulse, the voltage rise, voltage sags, voltage interruption, the impact of current, frequency of abnormal

Input parameter

Measuring circuit 1P2W, 1P3W, 3P3W, 3P4W

The fundamental frequency of the measuring circuit 50Hz/60Hz

Number of input channels Voltage, current, 4

Measurement range Voltage Measurement Range: Nominal value: 100V, 230V, 400V, maximum 1000V

Current measurement range: Depending on the current clamp, current clamp the output voltage signal, the maximum voltage: 10V peak

Environmental security parameters

Use of the environment 0 ° C to +45 ° C, humidity 90rh%

Storage environment -20 ° C to +50 ° C, 95RH% humidity (non-condensing)

Power input voltage +100VAC ~ +240VAC

Electromagnetic Compatibility Level 3: GB / T 17626.2-2006 Electrostatic Discharge Immunity

Level 3: GB / T 17626.3-2006 RF electromagnetic radiation the Immunity

Level 3: GB / T 17626.4-2008 electrical fast transient burst immunity

Level3: GB / T 17626.5-2008 surge (impact) Immunity

Level 3: GB / T 17626.8-2006 frequency magnetic field immunity

Level 3: GB / T 17626.9-1998 Pulse magnetic field immunity

Level 3: GB / T 17626.12 -1998 Oscillatory waves immunity

Environmental reliability GB/T 2423.1-2008 low temperature

GB/T 2423.2-2008 high temperature

GB/T 2423.4-2008 alternating hot and humid

GB/T 2423.5-1995 impact

GB/T 2423.10-2008 vibration

GB/T 2423.22-2002 temperature changes

Dustproof, waterproof IP20(GB 4208-93/IEC 529: 1989)

Security 500V/10M, 2KV: GB/T 15479-1995

External interface parameters

USB Device 1 The upload power quality data

TF card to expand storage 1 Built-in capacity Optional, up to 8G

Battery 1 4500mAh Ni-MH battery

LCD 1 26 million color 5.6-inch LCD screen with a resolution of 640 * 480

Voltage and current measurement interface 8 Test voltage and current input port

Frequency

Measurement method 10 waveform (50Hz) the calculated frequency

Display Display of a channel frequency value

Measuring range / resolution 50.0000Hz/0.0001Hz

Measurement bandwidth 42.5000~57.5000Hz

Measurement accuracy ±0.001Hz

1/2 rms voltage 1/2 rms, current

Measurement method Once every two cycle operations, a waveform operations per cycle to take 1/2 cycle

Sampling Frequency 200K

Measuring range / resolution 120V/0.01, 230V/0.01, 400V/0.01, Based on the use of current clamp

Measurement accuracy 0.1% of the nominal voltage

RMS voltage

Measurement method 10 waveforms (50Hz) the operator

Display Per channel RMS voltage

Sampling Frequency 200K

Measuring range / resolution 120V/0.01, 230V/0.01, 400V/0.01

Display Current per channel RMS

Measuring range / resolution Based on the use of current clamp

Harmonic voltage, harmonic current

Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles

Window points Every 10 cycles of 5120 points

Display Histograms, tables

Sampling Frequency 200KHz

Number of measurements 0~50

Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg

voltage harmonics less than 1% of the nominal value: Error is less than 0.05% rdg

the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg

current harmonics is less than 3% of the nominal value: Error is less than 0.05% of the nominal voltage

interharmonic voltage interharmonic current

Display Form

Number of measurements 1~16

High harmonic voltage, high harmonic currents

Measurement method Every 10 cycles of 5120 points

Number of measurements 1 to 35 group

Active power, reactive power, apparent power

Measurement method Active power: 10 cycles computing

Apparent power: Valid values of voltage and current operations

Reactive Power: apparent power, active power is calculated

Display Real-time data display

Measuring range / resolution Determined based on the voltage and current range

Measurement accuracy ±0.5%rdg

Power Factor

Measurement method Rms, current rms voltage, active power is calculated

Measuring range / resolution -1.0000~1.0000

Measurement accuracy ±1%rdg

Voltage unbalance, current unbalance (negative and zero sequence)

Measurement method when 3-phase 3-wire or 3-phase 4-wire, calculate by three-phase fundamental ingredients

Display Voltage unbalance

current imbalance

Measuring range 0.00%~100%

Measurement accuracy Voltage unbalance: ± 0.5%

Current imbalance: ± 0.5%

Voltage fluctuations

Measurement method Half-wave to calculate the mean square

Display The fluctuation trends, real-time values of voltage fluctuation

Measurement accuracy ±1%

IEC Flicker

Measurement Item The short flicker (PST), long flicker (Plt)

Measurement method According to IEC61000-4-15 10 minutes PST continuous measurement, continuous measurement and calculation 2 hours Plt

Display The flicker trends, Pst value, Plt

Measuring range 0~20

Measurement accuracy ±5%

The impact of current

Measurement method Half-wave rms current exceeds the set value of the positive impact of current

Display The impact of current waveform, the impact of the current maximum

Measurement accuracy 0.10%

Measurement method Temporary swell: half-wave rms voltage positive direction exceeds a set value, it is determine as Temporary swell

temporary sag: Valid values are negative direction exceeds a set value, determine as temporary sag

Short interruptions: half-wave RMS voltage exceeds the set value in the negative direction, the decision for an instant interrupt

Display Temporary swell, sag, short interruptions waveform duration, amplitude etc.


Company Contact:


  • Phone: 861085782698

  • Address: 01117-8 Fortune Street No.67 Chaoyang Road, Chaoya, Beijing , China

  • Email: Email


Published date: July 3, 2013

  • Business Description: involved in international trade import export of goods, products, and services

Related listings



  • Laer Enginetachometer Ged 2600
    Laer Enginetachometer Ged 2600
    Equipment - Testing / Measuring - guangzhou landtek isntruments - China - June 19, 2013 - contact company for price

    Application: 2 in 1 (Engine & Laser tachometer ) Applicable to the product departments of motor, fan, paper-product, plastics, chemical fiber, washing-machine, automobile, airplane, steamer etc. Model: GED2600 Application: 2-CIRCLE 1, 2, 3, 4-cylinde...

  • Digital Lux Meter Lx 9626
    Digital Lux Meter Lx 9626
    Equipment - Testing / Measuring - guangzhou landtek isntruments - China - June 19, 2013 - contact company for price

    Application: widely used in electro-optical sources, research teaching, metallurgy building, industry insp-ection as well as agriculture researching and illumination control. Model: LX9626 Measuring range:0-50000LUX 0-5000FC 3 RANGE: x1, x10, x100 re...

  • Dew Point Meter Ht 6292
    Dew Point Meter Ht 6292
    Equipment - Testing / Measuring - guangzhou landtek isntruments - China - June 19, 2013 - contact company for price

    Application: widely used in workshops, offices, plants, libraries, computer stations, laboratories and warehouses Model: HT6292 DEW POINT METER Measuring range: dew point –40-40℃ humidity 0-100%RH TEMP -10-65℃ Accuracy: dew point ±0.5T...



Safe Trade Tips

  • Ask for business references and check them
  • Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
  • Verify their business via their local Chamber of Commerce
  • Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
  • Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"