Standards
YY/T, etc.
Main Uses
The catheter leakage and compliance tester is mainly used to detect the leakage and compliance of medical catheters (such as the breathing circuits of ventilators and anesthesia machines).
Specifically, it can: Leakage Test: By applying a certain pressure inside the catheter and monitoring the rate or extent of pressure drop, it determines whether there is leakage in the catheter.
This is crucial for ensuring the sealing and safety of the catheter during medical procedures.
Compliance Test: Compliance refers to the ability of the catheter to deform when subjected to external forces.
The tester applies a certain pressure inside the catheter and measures the volume change of the catheter to evaluate its compliance.
This is of great significance for understanding the flexibility and elasticity of the catheter, as well as its applicability in medical applications.
Technical Parameters
Pressure Range: Usually determined according to the test object and application scenarios.
For example, the pressure range of medical breathing circuits may be between 0 - 300kPa.
The measurement range of the pressure sensors of some testers may be narrower, such as 0 - 50kPa, for routine compliance testing.
Pressure Accuracy: It is the key to ensuring the accuracy of test results.
Generally, an accuracy of ±0.1% or higher is required.
For example, when the measurement range of the pressure sensor is 0 - 50kPa, the accuracy may reach one - thousandth.
Flow Range: It should cover various flow situations that the tested catheter may encounter.
The common measurement range of flowmeters may be between 0 - 100L/min.
Flow Accuracy: Also important, generally an accuracy of ±1% or higher is required.
For example, when the range of the mass flow controller is 2L/min, the accuracy may be ±1%F.S. Volume Measurement Range and Accuracy: It should be adaptable to catheters of different volumes.
The volume measurement range can be from a few milliliters to several liters.
The volume measurement accuracy generally needs to reach ±0.1ml or higher to accurately calculate the compliance of the catheter.
Test Time Range: The tester should be able to flexibly set the time for leakage tests and compliance tests.
The time range for leakage tests may vary from a few seconds to several hours; in compliance tests, it can control the rate of pressure change and the time interval to accurately capture the volume changes of the catheter at different pressure stages.
Company Contact:
- Posted By: Standard Group (Hong Kong) Co., Ltd.
- Phone: 15715691047
- Address: Jindu Road, Minhang District, Shanghai , China
- Email:

- Website: https://www.standard-groups.com/en/
Published date: October 29, 2025
- Business Description: standard international group (hk) limited was established in 2003 and headquartered in hong kong.
the branch company in mainland is shanghai general standard textile testing technical company.
in changsha, wuhan, jinan, shenyang, chengdu, hangzhou and other places, standard groups has set up offices and after-sales service centers.
standard groups is an integrated supplier specialized in providing material test instruments and “the whole laboratory program” solutions.
the main products cover many areas: textile and apparel, leather and footwear, flammability testing, filter material testing, automotive interior, toy testing, non-woven and geo-membrane, carpet testing, luggage/furniture/office furniture testing, material and parts of automotive, weathering and light stability testing, ovens and environmental testing chambers, salt fog chambers, materials testing machines, 3d body scanning and manikin, air quality monitoring and measurement, package material testing, electrical safety testing, optical and spectroscopy instruments, lighting and color assessment, microscopy and legal inspection, and relative testing services.
Related listings
-
Catheter Residual Vacuum Tester Yy T 0339Equipment - Standard Group (Hong Kong) Co., Ltd. - China - October 29, 2025 - contact company for priceCompliance Standards YY/T 0339 - 2019 Suction Catheters for the Respiratory Tract, etc. Main Uses The catheter residual vacuum tester is mainly used to determine the physical properties of residual vacuum and leakage in suction catheters for the resp...
-
Catheter Flexibility TesterEquipment - Standard Group (Hong Kong) Co., Ltd. - China - October 29, 2025 - contact company for priceCompliance Standards YY/T 1554 - 2017. etc. ISO 10555 -Intravascular catheters- Sterile and single-use catheters ISO 11o70- Catheter introducers, dilators, and guidewires ASTM F2394-Guidewire mechanical property evaluation ASTM F2908- Stiffness and f...
-
Catheter Vacuum Leak TesterEquipment - Standard Group (Hong Kong) Co., Ltd. - China - October 29, 2025 - contact company for priceStandards GB 15812.1 - 2005 Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods GB 8368 Disposable Infusion Sets YY 0489 - 2004. etc. Main Uses The catheter vacuum leak tester is a professional device used to detect leak...
Safe Trade Tips
- Ask for business references and check them
- Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
- Verify their business via their local Chamber of Commerce
- Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
- Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
- This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"