Infusion Pump Flow Rate Tester - China
price: contact company for price
Compliance Standards
GB 8368 - 2018 Disposable Infusion Sets, etc.
Main Uses
The infusion set flow rate tester is an instrument specifically designed for measuring and monitoring the flow rate of infusion sets.
Its main uses include: - Flow Rate Measurement: Precisely measure the flow rate of the infusion set, usually displayed in milliliters per hour (ml/h) or drops per minute (gtt/min).
- Flow Monitoring: Monitor the changes in flow rate in real - time during the infusion process, and promptly detect abnormal flow rate situations, such as the flow rate being too fast, too slow, or blocked, to ensure the safety and effectiveness of the infusion process.
- Alarm Function: When the infusion flow rate exceeds the set normal range, the tester can emit audible and visual alarm signals to remind medical staff to take timely action and avoid potential medical risks.
- Data Recording and Storage: Record and store information such as flow rate data and time during the infusion process, which is convenient for medical staff to view and analyze, and helps track and evaluate the patient's infusion treatment.
Technical Parameters
The technical parameters of the infusion set flow rate tester may vary depending on the model and brand, but the following are some common parameter ranges: - Testing Range: The flow rate testing range is usually wide to adapt to different types and specifications of infusion sets.
For example, the testing range of some testers may reach 1 - 2000ml (varying according to the specifications of the catheter).
- Testing Accuracy: The tester usually has a high accuracy to ensure the accuracy of test results.
The accuracy of flow rate measurement may reach ± a certain percentage or ± a certain value (such as ±5ml/h or ±0.1gtt/min, etc.
).
- Static Water Level Height: The adjustable range of the static pressure head is usually between 0 - 1000mm to meet the requirements under different testing conditions.
- Temperature Control Range: The tester may be equipped with a temperature - control function to simulate the infusion situation under different temperature conditions.
The temperature - control range is usually between 5 - 90°C.
- Fixtures: Adapt to various catheters and are customized according to catheter specifications to ensure that the tester can firmly hold infusion sets of different specifications for testing.
- Flow Calculation: The tester may use the weighing method or other methods for flow calculation to ensure the accurate measurement of flow.
- Alarm Threshold: The tester usually allows users to set the alarm threshold, and the alarm is triggered when the flow rate exceeds the set range.
Company Contact:
- Posted By: Standard Group (Hong Kong) Co., Ltd.
- Phone: 15715691047
- Address: Jindu Road, Minhang District, Shanghai , China
- Email:

- Website: https://www.standard-groups.com/en/
Published date: October 29, 2025
- Business Description: standard international group (hk) limited was established in 2003 and headquartered in hong kong.
the branch company in mainland is shanghai general standard textile testing technical company.
in changsha, wuhan, jinan, shenyang, chengdu, hangzhou and other places, standard groups has set up offices and after-sales service centers.
standard groups is an integrated supplier specialized in providing material test instruments and “the whole laboratory program” solutions.
the main products cover many areas: textile and apparel, leather and footwear, flammability testing, filter material testing, automotive interior, toy testing, non-woven and geo-membrane, carpet testing, luggage/furniture/office furniture testing, material and parts of automotive, weathering and light stability testing, ovens and environmental testing chambers, salt fog chambers, materials testing machines, 3d body scanning and manikin, air quality monitoring and measurement, package material testing, electrical safety testing, optical and spectroscopy instruments, lighting and color assessment, microscopy and legal inspection, and relative testing services.
Related listings
-
Catheter Balloon Inflation Diameter TesterEquipment - Standard Group (Hong Kong) Co., Ltd. - China - October 29, 2025 - contact company for priceStandards ISO5367. YY0337.1 - 2002. GB/T15812.1 - 2005. YY 0321.1 - 2009. YY/T 0321.2 - 2021. YY 0321.3 - 2009. and YY0285.6. etc. Main Uses The catheter cuff inflated diameter tester is mainly used to measure the diameter of the cuffs of medical dev...
-
Catheter Airflow Resistance Tester Yy0461Equipment - Standard Group (Hong Kong) Co., Ltd. - China - October 29, 2025 - contact company for priceCompliance Standards YY0461 - 2003. etc. Main Uses The catheter airflow resistance tester is an important tool for evaluating the resistance of gas flow in catheters. It is specifically designed to measure the airflow resistance inside medical device...
-
Humidifying Bottle Performance TesterEquipment - Standard Group (Hong Kong) Co., Ltd. - China - October 29, 2025 - contact company for priceCompliance Standards YY/T 1610 - 2018 Main Uses The humidifier bottle performance tester is mainly used to detect various properties of humidifier bottles, including but not limited to leakage, pressure - resistance, humidification output, and overfl...
Safe Trade Tips
- Ask for business references and check them
- Use a payment method that offers better protection for all such as Letters of credit and verified professional escrow services. Avoid payments in advance such as money transfers
- Verify their business via their local Chamber of Commerce
- Search the internet using their website address, their business name, their phone and fax numbers, and their email addresses to see if you can find any feedback about them.
- Get to know more about scams and fraud to avoid: Internet Crime Complaint Center - Consumer Financial Protection Bureau
- This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"